Practical guide
Outdoor AQI vs Indoor PM2.5: Compare the Labels Before the Numbers
An outdoor AQI and a home particle reading describe different things. Compare pollutant, unit, location, averaging and update time before drawing a conclusion about the room.
An index and a concentration answer different questions
AirNow uses the U.S. Air Quality Index to communicate outdoor air quality and related public advice. The AQI has a shared colour scale for different pollutants. It is not a mass concentration unit, and the overall number does not necessarily describe particles: another pollutant, such as ozone, may be driving the reported value.
A home sensor may show a PM2.5 concentration, a proprietary score, a colour, or several separate channels. Start by reading the label and documentation. A concentration unit such as µg/m³ means micrograms per cubic metre: mass per volume. A number labelled AQI is an index. Identical-looking digits do not make those quantities interchangeable.
A sensor also measures at a particular place. The living-room reading does not describe every bedroom, the entire neighbourhood, or every pollutant. A quiet-looking display cannot establish that the home is safe for a particular person. Use outdoor public information for its intended purpose and the indoor reading for the narrower question its channel and evidence can support.
Read the labels before comparing the numbers
| Field | AirNow outdoor display | Household sensor | Useful conclusion |
|---|---|---|---|
| Quantity | AQI index and category; inspect the pollutant | Check PM concentration, AQI or vendor score | Do not subtract or divide unlike quantities |
| Location | Reported city/area or a selected map location | The actual occupied-room sensor position | Neither is automatically the other location |
| Pollutant | A reported AQI may be driven by ozone or particles | Only the channels the device actually measures | A PM reading does not establish gas concentrations |
| Time | Current NowCast, daily result or dated forecast | Update time and documented averaging/reporting | A short sample is not the same window as a daily index |
| Quality | Public AirNow data with preliminary quality checks | Model-specific evidence, siting and operating limits | Matching trends are useful context, not indoor validation |
On a narrow screen, scroll inside the table to read the last column. Keyboard readers can focus the table and use the arrow keys.
The table is a reading checklist, not a conversion formula. Fill in the actual display labels before entering values. If the app omits its averaging period or the meaning of its colour, record that as missing and consult the documentation or provider. Do not supply a plausible-sounding interval just to complete the comparison.
AirNow explains that its public data have preliminary checks and are distinct from the fully validated regulatory AQS record. That distinction does not make every consumer monitor equivalent to an AirNow monitor. EPA notes that consumer sensors can be biased or report questionable points; temperature, humidity and sensitivity can matter.
Keep place and time attached to every observation
A city dial, a nearby outdoor station and a device beside a kitchen counter represent different locations. Indoor sources and filtration can change what the home sensor experiences. For a representative room question, EPA advises avoiding immediate pollution sources and sinks, allowing airflow and considering the occupied space. A device beside an air-cleaner outlet can answer a different question from one across the room.
The current outdoor NowCast is also different from a raw instantaneous sample. AirNow uses multiple past hours and adjusts the averaging according to how stable or rapidly changing conditions are. Daily particle AQI concerns a 24-hour index; the ozone daily index uses an 8-hour period. Your device may report or average on another schedule. Read that schedule rather than assuming every timestamp means the same thing.
When recording two displays, note both update times, the time zone if shown and any gaps. “Opened at the same time” does not mean “measured the same air over the same interval.” For the detailed choice between tomorrow’s forecast, current information and a past day, use the separate AirNow time-product guide.
Make a comparison record in four steps
A reading record that preserves the limits
- Name the question
Write whether you are planning an outdoor activity, following a room trend, or checking a suspected source. One comparison does not answer all three.
- Identify both displays
Copy the pollutant, unit or score name, actual place, averaging information and update time. Keep any missing field explicitly unknown.
- Choose a valid comparison
Use like quantities and suitable time windows only when the evidence supports that comparison. Otherwise describe the two observations separately instead of calculating a ratio.
- Choose the next action
Check current local outdoor advice, investigate the room source or device setup, or obtain the missing model documentation. Preserve a record of what remains uncertain.
For a household trend, a consistent location and a brief activity log make changes easier to interpret. Moving the device, changing its settings or losing power can interrupt that consistency. Record those changes. A pattern can prompt a source-control check; it does not prove which source caused it or quantify a person’s exposure.
The aim is to make the next decision clearer, not to produce a reassuring number. If a household member has individual health instructions, those instructions and appropriate care matter alongside public outdoor information.
Two comparisons with different outcomes
A green outdoor category and an uncertain room display
Fictional example; no household was inspected and no live reading or device test was performed.
A household sees a green outdoor AQI category and a changing indoor PM channel while preparing dinner. The device is near the toaster. They want to conclude that the room must be clean because the outdoor category is good.
The useful record keeps the outdoor category separate from the indoor channel. They check the sensor location and the documented unit, note the cooking activity, and use the existing source-control guide for the household question. They do not relabel the indoor change as the outdoor AQI or infer a gas measurement.
Green outdoor information describes the outdoor product and its pollutant/time scope. The device location could be strongly influenced by the nearby activity, and the PM channel does not report every indoor pollutant. Neither display supplies a complete room inspection or individual health clearance.
Two numbers that tempt a percentage calculation
Fictional example; no household was inspected and no live reading or device test was performed.
Another reader has an outdoor AQI number and an indoor concentration labelled µg/m³. Both apps were opened together, and the indoor number looks smaller. The reader wants to publish a percentage showing how much cleaner the room is.
They do not calculate that percentage. The record shows “AQI index” for one quantity and “particle mass concentration” for the other, with different locations and uncertain matching windows. They can describe those labels and inspect a room trend, but leave the numerical improvement unproved.
Dividing a concentration by an index does not produce a meaningful concentration reduction. Even two concentration readings would need appropriate location, timing and device-performance evidence. An outdoor correction or a nearby station does not validate this indoor device.
Use the reading to find the next useful question
Do not treat a household sensor as a substitute for a certified life-safety alarm, an inspection or individual medical advice. A device might not measure the pollutant of concern or may be inaccurate under the actual conditions. EPA also cautions that an outdoor collocation correction may not apply indoors; comparing an indoor sensor with nearby outdoor monitors is not the outdoor installation-validation method transferred into the home.
If the unresolved question is the device’s capability, start with sensor selection and performance evidence. If the question is representativeness, use indoor placement and the activity log. For equipment choices, keep particle filtration and gas claims separate from the data-reading question.
The downloadable record lets you preserve both displays without pretending the fields are comparable. Keep it privately, leave missing inputs blank, and include the actual source or documentation you consulted. No reading is submitted through this page.
Sources and further reading
- AirNow: AQI BasicsEntire saved HTML main/article text checked November 13, 2026. Linked technical formulas, PDFs, model manuals and source images not read.
- AirNow: About the DataEntire saved HTML main/article text checked November 13, 2026. Linked technical formulas, PDFs, model manuals and source images not read.
- AirNow: Using the Air Quality IndexEntire saved HTML main/article text checked November 13, 2026. Linked technical formulas, PDFs, model manuals and source images not read.
- EPA: Frequent Questions About Air SensorsEntire saved HTML main/article text checked November 13, 2026. Linked technical formulas, PDFs, model manuals and source images not read.
- EPA: A Guide to Siting and Installing Air SensorsEntire saved HTML main/article text checked November 13, 2026. Linked technical formulas, PDFs, model manuals and source images not read.
- AirNow: How to Use This SiteEntire saved official HTML article/main text checked November 13, 2026. Linked PDFs, source images and model manuals not read.